Non-oriented electrical steel Electromagnetic performance standards
A Series
| Brand |
thickness (mm) |
Density (kg/dm3) |
Max iron loss P15/50 (W/kg) |
B50 (T) |
Min lamination factor (%) |
|
B35A210 |
0.35 |
7.60 |
2.10 |
1.62 |
95.0 |
|
B35A230 |
7.60 |
2.30 |
1.62 |
95.0 |
|
|
B35A250 |
7.60 |
2.50 |
1.62 |
95.0 |
|
|
B35A270 |
7.65 |
2.70 |
1.62 |
95.0 |
|
|
B35A300 |
7.65 |
3.00 |
1.62 |
95.0 |
|
|
B35A360 |
7.65 |
3.60 |
1.63 |
95.0 |
|
|
B35A440 |
7.70 |
4.40 |
1.64 |
95.0 |
|
|
B35A550 |
7.75 |
5.50 |
1.64 |
95.0 |
|
|
B50A230 |
0.50 |
7.60 |
2.30 |
1.62 |
96.0 |
|
B50A250 |
7.60 |
2.50 |
1.62 |
96.0 |
|
|
B50A270 |
7.60 |
2.70 |
1.62 |
96.0 |
|
|
B50A290 |
7.60 |
2.90 |
1.62 |
96.0 |
|
|
B50A310 |
7.65 |
3.10 |
1.62 |
96.0 |
|
|
B50A350 |
7.65 |
3.50 |
1.62 |
96.0 |
|
|
B50A400 |
7.65 |
4.00 |
1.63 |
96.0 |
|
|
B50A470 |
7.70 |
4.70 |
1.64 |
96.0 |
|
|
B50A600 |
7.75 |
6.00 |
1.66 |
96.0 |
|
|
B50A700 |
7.80 |
7.00 |
1.70 |
96.0 |
|
|
B50A800 |
7.80 |
8.00 |
1.70 |
96.0 |
|
|
B50A1000 |
0.65 |
7.85 |
10.00 |
1.70 |
96.0 |
|
B50A1300 |
7.85 |
13.00 |
1.70 |
96.0 |
|
|
B65A470 |
7.65 |
3.70 |
1.70 |
97.0 |
|
|
B65A600 |
7.75 |
4.70 |
1.70 |
97.0 |
|
|
B65A700 |
7.75 |
4.90 |
1.70 |
97.0 |
|
|
B65A800 |
7.80 |
8.00 |
1.70 |
97.0 |
|
|
B65A1000 |
7.80 |
10.00 |
1.70 |
97.0 |
|
|
B65A1300 |
7.85 |
13.00 |
1.70 |
97.0 |
AH Series
| Brand |
thickness (mm) |
Density (kg/dm3) |
Max iron lossP15/50 (W/kg) |
B50 (T) |
Min lamination factor(%) |
|
B35AH230 |
0.35 |
7.65 |
2.30 |
1.66 |
95.0 |
|
B35AH250 |
7.65 |
2.50 |
1.67 |
95.0 |
|
|
B35AH300 |
7.70 |
3.00 |
1.69 |
95.0 |
|
|
B50AH300 |
0.50 |
7.65 |
3.00 |
1.67 |
96.0 |
|
B50AH350 |
7.70 |
3.50 |
1.70 |
96.0 |
|
|
B50AH470 |
7.75 |
4.70 |
1.72 |
96.0 |
|
|
B50AH600 |
7.75 |
6.00 |
1.72 |
96.0 |
|
|
B50AH800 |
7.80 |
8.00 |
1.74 |
96.0 |
|
|
B50AH1000 |
7.85 |
10.00 |
1.75 |
96.0 |
AR Series
| Brand |
thickness(mm) |
Density (kg/dm3) |
Max iron lossP15/50 (W/kg) |
B50 (T) |
Min lamination factor (%) |
|
B35AR300 |
0.35 |
7.80 |
2.30 |
1.66 |
95.0 |
|
B50AR300 |
0.50 |
7.75 |
2.50 |
1.67 |
95.0 |
|
B50AR350 |
7.80 |
3.00 |
1.69 |
95.0 |
Notes.
a. Testing based on GB/T3655-2008.
b. The test specimen is half in longitudinal and half in transverse direction.
c. For stress relieved annealed high-efficiency non-oriented electrical steel AR series products, the magnetic property test is only applicable to the state of the specimen after 2 hours of stress relieved annealing at 750°C.
d. P15/50 indicates the core loss per unit kg of specimen at a maximum magnetic induction of 1.5 T and a frequency of 50 Hz. P10/400 indicates the core loss per kg specimen at a maximum magnetic induction of 1.0T and a frequency of 400Hz.
e. B50 indicates the magnetic induction strength corresponding to the magnetic field strength of 5000A/m.

It-tags Popolari: non-oriented electrical steel electromagnetic performance standards, China, suppliers, manufacturers, factory, buy, price, pricelist, for sale, in stock, free sample